11/7/2023 0 Comments White rodgers 50t35 manual![]() ![]() Valve sequence period is the cumulative total amount of time that the gas valve ![]() Period during which the valve and ignition source is activated, attempting toĪdditional ignition attempts if the original ignition attempt is unsuccessful. The ignition means prior to the lockout time. The period of time between energizing the main gas valve and deactivation of Initial delay between thermostat contact closure and trial for ignition.ĭuration of ignitor warm-up time on the first 64 attempts.ĭuration of ignitor warm-up time if the control retries. (All times are in seconds, unless noted otherwise) Gases Approved: Natural, Manufactured, Mixed, Liquified Petroleum, and LP Gas Air Mixtures are all approved for use. *Measured with a DC microammeter in the flame probe leadĥ% to 93% relative humidity (non-condensing) Minimum current to insure flame detection: 1 µa DC* Maximum current for non-detection: 0.1 µa DC* Maximum allowable leakage resistance: 100 M ohms Valve Relay: 1.5 amp 24 VAC 60 Hz 0.6 pf Ignitor Relay: 5.0 amp 120 VAC 60 HzĬirculator Relay: 11 FLA–26.0 LRA 120 VAC Humidifier Load Rating: 0.5A 24 VACĮlectronic Air Cleaner Load Rating: 1A 120 VAC ![]()